YKY 0.6/1 kV 2x2.5 Power cable with copper conductor and PVC insulation 112271071D1000

Index local:
KEC027NKTQ
Numéro de catalogue:
112271071D1000
Code EAN:
5907802033081
Producteur: NKT
Produit de grande taille
Prix:
5,71 zł
gross / mc.
(y compris la TVA 23%)
En rupture de stock
Sur commande
Ajouter à la demande de devis
Imprimer

Données techniques

  • PKWIU
    27.32.13.0

Autres données techniques

  • Conductor surface
    Bare
  • Conductor category
    Class 1 = solid
  • Number of cores
    2
  • Specification core insulation
    Other
  • Laminated sheath
    No
  • Żyła ochronna
    No
  • Outer semi-conducting layer
    No
  • Drain wire
    No
  • Number of pilot/reduced conductors
    0
  • Armouring
    No
  • Specification material outer sheath
    Other
  • Conductive coating
    No
  • Longitudinal water blocking screen
    No
  • Reaction-to-fire according to EN 13501-6: Smoke production
    None
  • Reaction-to-fire according to EN 13501-6: Acidity
    None
  • Halogen free according to EN IEC 60754-2
    No
  • Low smoke (according to EN 61034-2)
    No
  • Trwałość izolacji zgodnie z IEC 60331
    No
  • Circuit integrity
    No
  • Outer diameter approx.
    10.24 mm
  • Permitted cable outer temperature after assembling without vibration
    -35 ... 70 °C
  • Nominal voltage U
    1 kV
  • Nominal cross section conductor
    2.5 mm²
  • Shape of conductor
    Round
  • Material core insulation
    Polyvinyl chloride (PVC)
  • Core identification
    Colour
  • Fibre optic elements
    No
  • Inner semi-conducting layer
    No
  • Screen
    No
  • Lead sheath
    No
  • Concentric conductor
    None
  • Material outer sheath
    Polyvinyl chloride (PVC)
  • Colour outer sheath
    Black
  • Longitudinal water blocking conductors
    No
  • Reaction-to-fire according to EN 13501-6: Class
    Eca
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
    None
  • Halogen free according to EN 60754-1/2
    No
  • Flame retardant
    According to IEC/EN 60332-1-2
  • Low smoke according to EN IEC 61034-2
    No
  • Wytrzymałość (trwałość) izolacji
    No
  • Olejoodporny zgodnie z IEC 60811-404
    No
  • Max. conductor temperature
    70 °C
  • Nominal voltage U0
    0.6 kV

Dane CPR (Construction Products Regulation)

  • Wydzielane substancje niebezpieczne:
    NPD
  • Numer referencyjny DoP (DWU)
    DOP000032
  • Oznaczenie produktu
    YKY 0.6/1 kV 2x2,5
  • Reakcja na ogień:
    Eca
  • Zharmonizowana specyfikacja techniczna (norma):
    EN 50575:2014, EN50575:2014/A1:2016
  • Zastosowanie:
    Dostawa energii (oraz zastosowania komunikacyjne) w budynkach i innych obiektach budowlanych w celu ograniczenia powstawania i rozprzestrzeniania się ognia i dymu

Détails du fabricant

  • Producteur
    NKT S.A.
  • Adresse
    43-502 Warszowice Gajowa 3 Polska

Fichiers à télécharger

Signaler une erreur