Miniature circuit breaker, 10kA, B, 3+N, 6A NBN606

local index:
ALI207HAGE
Catalog No:
NBN606
EAN code:
3250614614446
Manufacturer: HAGER
Rated frequency [Hz]: 50/60
Depth [mm]: 70
Number of poles: 4
Price:
82,30 €
gross / pcs.
(including VAT 23%)
Delivery in 3h
up to 10 weeks (business days)
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

Circuit breakers 0.5 - 63 A. Type B, C and D
Rated short-circuit breaking capacity 10000 A:
• rated ultimate short-circuit breaking capacity (Icu): 15 kA, in accordance with PN-EN 60947-2,
• energy limitation class: 3,
• rated operational voltage:
230/400 V AC - single-pole circuit breaker,
400V AC - omnipolar circuit breaker,
• can be used in DC circuits,
• a wide range of accessories, including insulating barriers between poles,
• possibility of connection using vertical and horizontal comb busbars,
• cage terminals: wire up to 35 mm², stranded wire up to 25 mm²,
• description field with a protective flap,
• top and bottom openable mounting clips,
• degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.

Technical data

  • Rated frequency [Hz]
    50/60
  • Number of poles
    4
  • Rated insulation voltage [V]
    500
  • power loss [W]
    5.44
  • Working temperature [°C]
    -25 to 60
  • Electrical endurance (number of cycles)
    4000
  • Connection type
    With a screw
  • AC rated voltage [V]
    230/400
  • Depth [mm]
    70
  • Tightening torque [Nm]
    2.8
  • Rated current [A]
    6
  • Width [mm]
    70
  • Height [mm]
    83
  • Mechanical durability (number of cycles)
    20000
  • Number of modules
    4
  • PKWIU
    27.12.22.0

Other technical data

  • Built-in depth
    70 mm
  • Number of poles (total)
    4
  • Rated current
    6 A
  • Rated insulation voltage Ui
    500 V
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
    10 kA
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
    10 kA
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
    15 kA
  • Current limiting class
    3
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 25 mm²
  • Release characteristic
    B
  • Number of protected poles
    3
  • Rated voltage
    400 V
  • Rated impulse withstand voltage Uimp
    6 kV
  • Voltage type
    AC
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
    30 kA
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    Yes
  • Pollution degree
    2
  • Width in number of modular spacings
    4
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 35 mm²

Bulk packaging

A kind of package Karton Pakiet Paleta
Quantity 1 pcs. 3 pcs. 36 pcs. 864 pcs.
Weight (kg) 0,410 1,330 16,400 416,600
Width (m) 0,070 0,097 0,315 0,800
Length (m) 0,087 0,082 0,230 1,070
Depth (m) 0,073 0,229 0,360 1,200