Contactor DILM40-EA 3P 18.5kW/400V IP00 230VAC 190009

Índice local:
ATC035MOEL
Número de catálogo:
190009
Código EAN:
4015081880058
Fabricante: EATON
Number of main contacts NO: 3
Overvoltage category: III
Number of poles: 3
Precio:
648,91 zł
gross / uds.
(IVA incluido 23%)
Accesible 17 uds.
Recogida en 1h
Cantidad uds.
(múltiple:
1
)
Añadir a solicitud de presupuesto
Añadir al portapapeles
Imprimir

Descripción del producto

Continuous operation requires highly reliable components .DILM contactors achieve not only the best durability parameters in the AC-3 category, but also great for heavy duty pulsed AC-4. This increases machine and plant safety also during the test and change phase.

Datos técnicos

  • Number of main contacts NO
    3
  • Number of poles
    3
  • AC control voltage [V]
    230
  • Level of security
    IP00
  • Mechanical durability [Number of connections]
    10000000
  • Rated surge voltage [V]
    8000
  • Rated operational current Ie for AC-1 400V [A]
    60
  • Rated operational current Ie for AC-4 400V [A]
    18
  • Overvoltage category
    III
  • Installation
    On the TH-35 rail
  • Rated insulation voltage [V]
    690
  • Degree of contamination
    3
  • Maximum operating voltage [V]
    690
  • Rated operating power at AC-3 400V [kW]
    18.5
  • Rated operational current Ie for AC-3 400V [A]
    40
  • Rated operating power at AC-4 400V [kW]
    9

Otros datos técnicos

  • Rated control supply voltage AC 50 Hz
    230 ... 230 V
  • Rated control supply voltage DC
    0 ... 0 V
  • Rated operation current Ie at AC-1, 400 V
    60 A
  • Rated operation power at AC-3, 400 V
    18.5 kW
  • Rated operation power at AC-4, 400 V
    9 kW
  • Modular version
    No
  • Number of auxiliary contacts as normally closed contact
    0
  • Number of normally closed contacts as main contact
    0
  • Rated control supply voltage AC 60 Hz
    240 ... 240 V
  • Voltage type for actuating
    AC
  • Rated operation current Ie at AC-3, 400 V
    40 A
  • Rated operation current Ie at AC-4, 400 V
    18 A
  • Rated operation power NEMA
    22 kW
  • Number of auxiliary contacts as normally open contact
    0
  • Type of electrical connection of main circuit
    Screw connection
  • Number of normally open contacts as main contact
    3

Detalles del fabricante

  • Fabricante
    Eaton Electric Sp. z o.o.
  • Dirección
    80-299 Gdańsk Galaktyczna 30 Polska

Empaquetado a granel

una especie de paquete Skrzynia Karton Skrzynia Karton
Cantidad 1 uds. 1 uds. 1 uds. 1 uds.
Peso (kg) 0,872 0,923 0,872 0,923
Volumen (m3) 0,001 0,001 0,001 0,001
Ancho (m) 0,057 0,057 0,057 0,057
Longitud (m) 0,134 0,151 0,134 0,151
Profundidad (m) 0,117 0,118 0,117 0,118

Archivos para descargar

Informar de un error