125A four-pole load switch HA451

Místní index:
ALI221HAGE
Katalogové číslo.:
HA451
EAN kód:
3250613114510
Výrobce: HAGER
Number of poles: 4
Rated insulation voltage [V]: 800
Rated current [A]: 125
Cena:
604,80 zł
gross / kusů.
(včetně DPH 23%)
do 10 týdnů
Na zakázku
Množství kusů.
(vícenásobné:
1
)
Přidat do žádosti o cenovou nabídku
Přidat do schránky
Vytisknout

Popis produktu

Isolating Load Switch. It is perfectly adapted to meet current requirements resulting from everyday electrical installation practice.

Current:

  • Current carrying capacity of AC21 in category A: 125 A ,
  • Rated operational current (AC23), category A: 125 A,
  • Current carrying capacity AC21 category B: 125 A,
  • Allowable current load AC22 Category A: 125 A,
  • Allowable current load AC22 Category B: 125 A,
  • Rated operational current (AC23), Category B: 125 A,
  • Conventional short-circuit current: 20 kA,
  • Short-circuit current with gI-gG fuses: 50 kA,
  • Rated short-time withstand current Icw: 7 kA,
  • short-time withstand current 1s: 7 kA.

Power:

  • Power supply below 440/500V 50Hz: 63 kW
  • Rated power below 660 V, 50 Hz: 55 kW
  • Active power below 380/415 V, 50 Hz: 63 kW
  • Rated switching power at 400 V rated voltage for AC1: 82 kW
  • Total power loss at rated current: 5.4 W
  • Power loss per pole at rated current: 1.8 W

Technické údaje

  • Number of poles
    4
  • Rated current [A]
    125
  • power loss [W]
    5.4
  • Connection type
    Vice
  • Conventional short-circuit current [kA]
    20
  • Rated operational current [A]
    125
  • PKWIU
    27.12.22.0
  • Rated insulation voltage [V]
    800
  • Level of security
    IP00
  • Power loss per pole [W]
    1.8
  • Rated switching voltage [V]
    380/415
  • Rated surge voltage [V]
    8000
  • Conductor cross-section (wire) [mm²]
    50

Další technické údaje

  • Version as main switch
    Yes
  • Version as safety switch
    Yes
  • Version as reversing switch
    No
  • Max. rated operation voltage Ue AC
    415 V
  • Rated permanent current Iu
    125 A
  • Rated permanent current at AC-21, 400 V
    125 A
  • Rated operation power at AC-23, 400 V
    56 kW
  • Conditioned rated short-circuit current Iq
    50 kA
  • Number of auxiliary contacts as normally closed contact
    0
  • Number of auxiliary contacts as change-over contact
    0
  • Motor drive integrated
    No
  • Device construction
    Built-in device fixed built-in technique
  • Suitable for front mounting centre
    No
  • Suitable for intermediate mounting
    No
  • Type of control element
    Long turning handle
  • Type of electrical connection of main circuit
    Cable clamp
  • Degree of protection (IP), front side
    IP00
  • Width
    120 mm
  • Depth
    170 mm
  • Version as maintenance-/service switch
    Yes
  • Version as emergency stop installation
    No
  • Number of switches
    1
  • Rated operating voltage
    380 ... 415 V
  • Rated permanent current at AC-23, 400 V
    125 A
  • Rated short-time withstand current lcw
    7 kA
  • Switching power at 400 V
    82 kW
  • Number of poles
    4
  • Number of auxiliary contacts as normally open contact
    0
  • Motor drive optional
    No
  • Voltage release optional
    No
  • Suitable for front mounting 4-hole
    No
  • Suitable for distribution board installation
    Yes
  • Colour control element
    Black
  • Interlockable
    Yes
  • With pre-assembled cabling
    No
  • Degree of protection (NEMA)
    Other
  • Height
    135 mm

Podrobnosti o výrobci

Velkoobjemová balení

Typ obalu Karton Pakiet Paleta Karton Pakiet Paleta
Množství 1 kusů. 6 kusů. 144 kusů. 1 kusů. 6 kusů. 144 kusů.
Hmotnost (kg) 1,433 8,975 238,400 1,433 8,975 238,400
Šířka (m) 0,140 0,320 0,800 0,140 0,320 0,800
Délka (m) 0,090 0,210 1,000 0,090 0,210 1,000
Hloubka (m) 0,180 0,370 1,200 0,180 0,370 1,200
Nahlásit chybu