CZF-BR phase loss and unbalance sensor CZF-BR

Indice locale:
APL105FIFQ
Numero di catalogo:
CZF-BR
Codice EAN:
5908312593119
Produttore: F&F
Trip voltage unbalance [V]: 40-80
Voltage hysteresis [V]: 5V~
Number of contacts: 0NO 0NC
Prezzo:
22,94 €
gross / pezzi
(inclusa IVA 23%)
Consegna in 3 ore
fino a 2 settimane (giorni lavorativi)
Raccolta in 1h
Quantità pezzi
(multiplo:
1
)
Aggiungi alla richiesta di preventivo
Aggiungi agli appunti
Stampa

Descrizione del prodotto

Intended use
The phase loss sensor is designed to protect the motor  power supply from a three-phase network in the event of a voltage failure in at least one phase or asymmetry of voltage between phases, threatening the destruction of the motor.Action
Power failure in at least one, any phase  or Voltage unbalance [V] between the phases above the activation threshold will cause the motor to be switched off. The switch-off will take place with a delay of 4 seconds, which prevents accidental disconnection of the motor in the event of a momentary voltage drop. Reactivation will occur automatically when  voltage increase by 5V above the operating voltage  (i.e. the value of the voltage hysteresis). With the above anomalies, the engine cannot be started.

Dati tecnici

  • Trip voltage unbalance [V]
    40-80
  • Number of contacts
    0NO 0NC
  • Power [W]
    1.6
  • Shutdown delay [s]
    4
  • connection
    2.5mm screw terminals
  • Dimensions
    2 modules (35mm)
  • Package height [mm]
    150
  • Package weight [kg]
    0.1
  • Voltage hysteresis [V]
    5V~
  • Power control
    3×LED green
  • Installation
    On the TH-35 rail
  • load current [A]
    <10
  • Working temperature [°C]
    -25-50
  • Power
    3×400/230V+N
  • Package width [mm]
    40
  • PKWIU
    27.12.24.0

Altri dati tecnici

  • Type of electric connection
    Screw connection
  • Rated control supply voltage AC 50 Hz
    3 ... 400 V
  • Phase sequence monitoring
    No
  • Function under voltage detection
    No
  • Phase imbalance monitoring
    Yes
  • Min. adjustable off-delay time
    4 s
  • Number of contacts as normally open contact
    1
  • Depth
    65 mm
  • With detachable clamps
    No
  • Voltage type for actuating
    AC
  • Phase failure detection
    Yes
  • Function over voltage detection
    No
  • Voltage measuring range
    140 ... 270 V
  • Max. permitted off-delay time
    4 s
  • Height
    90 mm

Dettagli del produttore

  • Produttore
    F&F Filipowski S.K.
  • Indirizzo
    95-200 Pabianice Konstantynowska 79/81 Polska

Imballaggio sfuso

Una specie di pacchetto Sztuka
Quantità 1 pezzi
Peso (kg) 0,098
Larghezza (m) 0,041
Lunghezza (m) 0,095
Profondità (m) 0,070
Segnala un errore