MPI-530 multifunctional meter + license for the SONEL PE6 program WMPLMPI530SPE6

Místní index:
NPI034SONE
Katalogové číslo.:
WMPLMPI530SPE6
EAN kód:
5907624030633
Výrobce: SONEL
Model: MPI-530
Hidden: MPI Summer 2023
Cena:
2560,69 €
gross / kusů.
(včetně DPH 23%)
Dodání do 3 hodin
Není skladem
Vyzvednutí za 1h
Množství kusů.
(vícenásobné:
1
)
Přidat do žádosti o cenovou nabídku
Vytisknout

Popis produktu

Multifunctional electrical installation meter

Professional and versatile

Multifunctional electrical installation meter Sonel MPI-530 is used for precise measurement of parameters of electrical installations. The device has been constructed in accordance with the requirements of the PN-EN 61557 standard. It allows you to perform all measurements related to protection against electric shock described in the PN-EN 61557 standard. -HD 60364-6.

The specialist Sonel MPI-530 meter is distinguished by extensive earthing measurement functions - additional clamp methods and soil resistivity. Using the optional AuroISO-1000C adapter, it is also possible to automatically measure the insulation resistance in sockets and for 3-, 4- and 5-wire cables.

With the Sonel MPI-530 meter, you can also perform a illuminance test. An additional external probe is required for this. The device enables registration and analysis of network parameters - including harmonics up to the 40th. Another advantage of the meter is a durable housing with IP54 resistance class, which protects the device against mechanical damage, dust or splashes.

Features

The meter is characterized by < strong>broad possibilities in the field of functionality. It combines the measurement capabilities of several devices, while ensuring equally good accuracy.

  • The MPI-530 device can be used to perform all acceptance measurements of electrical installations in accordance with applicable regulations:
    • fault loop impedance (also in circuits with RCDs),
    • parameters of RCDs,
    • insulation resistance,
    • earth resistance (4 measurement methods + ground resistivity measurement),
    • continuity of protective and equipotential bonding,
    • illuminance,
    • phase sequence test,
    • test of motor rotation direction.
  • The MPI-530 can record 50/60 power quality parameters  Hz:
    • L1 voltage – average values up to 500 V,
    • L1 current – average values, current measurement in the range up to 3 kA (depending on the current clamps used),
    • frequency in the range of 40 Hz – 70 Hz,
    • active power (P), reactive power (Q), apparent power (S),
    • power factor (PF), cosφ,
    • harmonics (up to the 40th in voltage and current),
    • harmonic distortion factor THD for current and voltage

< strong>Inspection of installation safety

With the instrument, you can control home and industrial electrical installations in terms of safety. Measurements can be easily automated by:

  • testing residual current circuit breakers in Auto mode,
  • using the WS type adapter to test the installation through a standard 230 socket V.
  • use of the AutoISO-1000C adapter to test the insulation resistance of 3-, 4- and 5-core wires.

Memory structure

The memory structure is in the form of a tree. It allows you to save tens of thousands of results in the CLIENT-OBJECT-ROOM-MEASURING POINT system, which helps in the subsequent creation of a transparent protocol. This structure can be prepared in the meter before starting work. Entering data into the device is facilitated by the QWERTY keyboard, which connects to it via Bluetooth.

Built-in help system

The device has built-in help screens with measurement diagrams. Thanks to this, you can easily and quickly check how to connect a given system depending on the type of measurement.

Increased resistance to environmental conditions

The meter The MPI-530 will cope well in harsh environmental conditions. Protection against the ingress of dust and water is provided by a unique housing with an IP54 tightness level. It is resistant to mechanical damage, and the special design allows you to easily protect the display by sliding the meter cover. In addition to the fact that it protects against damage, it also allows you to conveniently carry and use the device in various positions.

Communication and software

< p>Through the USB port or using Bluetooth wireless communication, you can transfer the measurement data to a computer. In order to generate a test report in the field of electric shock protection, use the Sonel Electrical Measurements program. Saving the downloaded resources to the simplest formats and printing them is provided by Sonel Reader.

 

< thead> < /tr> < td>0.12 Ω…400 Ω to IEC 61557-4 < /tr>
Measurement functions Measurement range Display range Resolution Accuracy
Fault loop impedance        
ZL-PE, ZL-N, ZL-L fault loop 0.13 Ω …1999.9 Ω to IEC 61557 0.00 Ω…1999 Ω da 0.01 Ω from ±(5% m.v. + 0, 03 Ω)
ZL-PE fault loop in RCD mode from 0.50 Ω…1999 Ω to IEC 61557 0.00 Ω…1999 Ω da 0.01 Ω from ±(6% m.v. + 5 digits )
Measurements of RCD Parameters        
RCD tripping test and tripping time measurement tA measuring current 0.5 IΔn, 1 IΔ n, 2 IΔn, 5 IΔn        
RCD of general type and short delay        
• TN/TT network 0ms…300ms 0ms…300ms 1ms ±(2% m.v. + 2 digits)
RCD selective 0 ms…500 ms 0 ms…500 ms 1 ms ±(2% m.v. + 2 digits)
Measurement of RCD tripping current IA measuring current 0.2 IΔn…2, 0 IΔn        
for sinusoidal residual current (type AC) 3.3 mA…1000 mA 3.3 mA…1000 mA da 0.1 mA ±5% IΔn
for 1-way differential current and 1-way differential current with 6 mA DC bias (type A) 3.5 mA…700 mA 3.5 mA…700 mA is 0.1 mA ±10% IΔn
for DC residual current (type B) 2.0 mA…1000 mA 2.0mA…1000mA for 0.1mA ±10% IΔn
Earth Resistance        
3- and 4-wire method from 0.50 Ω…1.99 kΩ to IEC 61557-5 0.00 Ω…1.99 kΩ da 0.01 Ω from ±(2% m.m. + 3 digits)
3-wire method + clamp 0.00 Ω…1.99 kΩ 0.00 Ω…1.99 kΩ will give 0.01 Ω ±(8% m.v. + 4 digits)
2-clamp method 0.00 Ω…99.9 kΩ 0.00 Ω…99.9 kΩ< /td> da 0.01 Ω from ±(10% m.v. + 4 digits)
Soil resistivity< /strong> 0.0 Ωm…99.9kΩm 0.0 Ωm…99.9kΩm da 0.1 Ωm Depends on RE measurement accuracy
Insulation resistance   ;      
Measuring voltage 50 V 50kΩ…250MΩ according to IEC 61557-2 0 kΩ…250 MΩ equivalent to 1 kΩ from ±(3% m.v. + 8 digits)< /td>
100 V measuring voltage 100 kΩ…500 MΩ according to IEC 61557-2 0 kΩ…500 MΩ is 1 kΩ from ±(3% m.v. + 8 digits)< /td>
Measuring voltage 250 V 250 kΩ…999 MΩ according to IEC 61557-2 0 kΩ…999 MΩ is 1 kΩ from ±(3% m.v. + 8 digits)< /td>
500 V test voltage 500 kΩ…2.00 GΩ to IEC 61557-2 0 kΩ…2.00 GΩ for 1 kΩ from ±(3% m.v. + 8 digits )
Measuring voltage 1000 V 1000 kΩ…9.99 GΩ per IEC 61557-2 0 kΩ…9.99 GΩ for 1 kΩ from ±(3% m.v. + 8 digits )
Resistance of protective and equalizing conductors        
Continuity measurement of protective and equipotential bonding with ±200 mA 0.00 Ω…400 Ω da 0.01 Ω ±(2% m.v. + 3 digits)
Low current resistance measurement 0.0 Ω…1999 Ω 0.0 Ω&hellip ;1999 Ω da 0.1 Ω ±(3% m.v. + 3 digits)
Illuminance        
Lux measurement (lx) 0 lx…399.9 klx 0 lx…399.9 klx da 0.001 lx from ±(2% m.v. + 5 digits)
Fc measurement 0 fc…39 .99 kfc 0 fc…39.99 kfc is 0.001 fc from ±(2% m.v. + 5 digits)
Phase Sequence Indication Assisting, Inverse, UL-L Voltage: 95V…500V (45Hz…65Hz)      

 

< p>Single-phase recorder

The device is designed to work in the following networks:

  • with a nominal frequency of 50/60 Hz
  • < li>with rated voltages: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V

Systems of supported networks:

  • single phase
Parameter Range Maximum resolution Accuracy
Alternating voltage (TRMS) 0.0…500V 0.1V from ±(2% m.v. + 2 digits)
Alternating current (TRMS) depending on clamps* 0.1 mA from ±(5% m.v. + 3 digits) (error does not include clamp error)
Frequency 45.0…65.0 Hz 0.1 Hz ±(0.1% m.v. + 1 digit)< /td>
Active, reactive and apparent power 0 VA…1.5 MVA, 0 W…1.5 MW, 0 var…1.5 Mvar 1 VA, 1 W, 1 var from ±(7% m.v. + 3 digits)
cosφ and power factor (PF) 0.00…1.00 0.01 Accuracy is not specified
Harmonics      
Voltage 0.0…500V 0.1V from ±(5% m.v. + 3 digits)
Current depending on clamps* same as AC True RMS from ±(5% m.v. + 3 digits) (accuracy does not include clamp error
THD      
Voltage 0.0…999.9 % (relative to first harmonic) 0.1% ±5%
Current 0.0…999.9% (relative to first harmonic) 0.1% ±5% (accuracy does not include clamp error)
  • F-1A, F-2A, F-3A clamps: 0…3000 A AC (10,000 Ap-p)
  • C clamps -3: 0…1000 A AC (3600 Ap-p)
  • C-6A clamp: 0..10 A AC (36 Ap-p)

 

Alternating current (True RMS) measurement with clamps

< td>IP67
  C-3 C-6A F-1A F-2A F-3A
Rated current 1000A AC 10A AC 3000A AC 3000A AC 3000A AC
Frequency 30 Hz…10 kHz 40 Hz…10 kHz 40 Hz…10 kHz 40Hz…10kHz 40Hz…10kHz
Max. diameter of the measured cable 52 mm 20 mm 380 mm 250 mm 140mm
Minimum Basic Accuracy ≤0.3% ≤1% 1% 1% 1%
Battery powered - - - - -
Cable length 2m 2.2m 2.5m 2.5m 2.5m
Measurement Category III 600V< /td> IV 300V IV 600V IV 600V IV 600V
Enclosure rating IP40 IP40 IP67 IP67

 

Program for creating protocols from installation security tests

The latest version of the popular program for creating protocols from electrical measurements. PE6 simplifies the documentation process. It minimizes its time. It automates. All thanks to numerous built-in mechanisms, tools and functions.

Program features:

  • compliance of the printed protocol with the new PN-HD 60364-6 standards: 2016-07, PN-HD 60364-4-41:2017-09
  • cooperation with SONEL S.A. meters,
  • tree structure of the document,
  • extended protection and measurement point databases,
  • automatic calculation of required values,
  • automatic evaluation of measured results,
  • schedule of measurements,
  • inserting photos and drawings to protocols,
  • printing measurement controls and table descriptive labels,
  • calculating performed measurements,
  • printing invoices,
  • automatic completion of protocols with a series of data.

The program supports the creation of documentation after tests in the field of comprehensive control of measurement points and:

  • tripping efficiency (TN-S, TN-C, TN-C-S, TT, IT),
  • parameters of RCDs,
  • state insulation of circuits (TN-S, TN-C, TN-C-S, TT, IT),
  • the condition of insulation of electric cables,
  • the condition of the lightning protection system and earthing,
  • wire continuity,
  • insulation resistance of open and closed motors,
  • resistance of contactors,
  • resistance of circuit breakers,< /li>
  • transformer devices.

Hardware requirements:

  • Operating system: Windows 10
  • < li>Minimum resolution: 1024x768
  • Recommended resolution: 1920x1080

Technické údaje

  • Model
    MPI-530
  • Hidden
    MPI Summer 2023

Podrobnosti o výrobci

  • Výrobce
    SONEL SPÓŁKA AKCYJNA
  • Adresa
    58-100 UL. STANISŁAWA WOKULSKIEGO 11
  • DIČ
    8840033448
Nahlásit chybu