2P, 25A, 30mA residual current device CDC225J

Místní index:
ARP024HAGE
Katalogové číslo.:
CDC225J
EAN kód:
3250611619468
Výrobce: HAGER
Depth [mm]: 70
Number of modules: 2
Number of poles: 2
Bestsellery
Cena:
132,84 zł
gross / kusů.
(včetně DPH 23%)
Nejnižší cena od 30 dnů před slevou: 289,05 zł gross -156,21 zł
Cena výrobce: 295,20 zł gross
Dodání do 3 hodin
k dispozici 185 kusů.
Vyzvednutí za 1h
Množství kusů.
(vícenásobné:
1
)
Přidat do žádosti o cenovou nabídku
Přidat do schránky
Vytisknout

Popis produktu


RCDs Type AC

• RCDs with high and medium sensitivity, AC residual currents (sinusoidal alternating current),

• Rated operational voltage: 230/400 V AC - two-pole circuit breaker, 400 V AC - four-pole circuit breaker,

• rated residual operating current in the range from 10 mA to 500 mA,

• making capacity and breaking (Im): 1500 A,

• nominal short-circuit current (Inc): the value depends on the rated current of the short-circuit protection protecting the RCD,

• optical indicator of operating (opening/closing of the circuit breaker and tripping of the circuit breaker due to residual current),

• wide range of accessories,

• possibility of connection using vertical and horizontal comb busbars,

• cage terminals:

   - circuit breakers with a rated current of 16 ÷ 63 A: wire up to 25 mm2, stranded wire up to 16 mm2

   - circuit breakers with a rated current of 80 ÷ 125 A: wire up to 50 mm2, stranded wire up to 35 mm2,

• degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.



Technické údaje

  • Depth [mm]
    70
  • Number of poles
    2
  • Differential current [mA]
    thirty
  • Power dissipation [W]
    2.5
  • Height [mm]
    83
  • Breakdown voltage [V]
    500
  • Number of modules
    2
  • Rated insulation voltage [V]
    500
  • Rated current [A]
    25
  • Width [mm]
    35
  • Number of modules
    2
  • PKWIU
    27.12.23.0

Další technické údaje

  • Number of poles
    2
  • Rated current
    25 A
  • Rated insulation voltage Ui
    500 V
  • Mounting method
    DIN rail
  • Selective protection
    No
  • Short-circuit breaking capacity (Icw)
    6 kA
  • With interlocking device
    Yes
  • Additional equipment possible
    Yes
  • Width in number of modular spacings
    2
  • Ambient temperature during operating
    -25 ... 40 °C
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²
  • Rated voltage
    230 V
  • Rated fault current
    30 A
  • Rated impulse withstand voltage Uimp
    4 kV
  • Leakage current type
    AC
  • Short-time delayed tripping
    No
  • Surge current capacity
    0.25 kA
  • Frequency
    50 Hz
  • Degree of protection (IP)
    IP20
  • Built-in depth
    70 mm
  • Pollution degree
    2
  • Connectable conductor cross section solid-core
    1 ... 25 mm²

Podrobnosti o výrobci

Velkoobjemová balení

Typ obalu Karton Pakiet Paleta
Množství 1 kusů. 60 kusů. 1440 kusů.
Hmotnost (kg) 0,180 11,160 267,830
Šířka (m) 0,080 0,320 0,800
Délka (m) 0,040 0,210 1,050
Hloubka (m) 0,100 0,360 1,200