Digital clamp meter designed for direct measurement of alternating current up to 400 A. The device can also measure direct and alternating voltages up to 600 V (using test leads). Additional functions include measurement of resistance and continuity of connections with acoustic signaling, and temperature measurement using the probe supplied with the meter.
Nominal conditions of use:
- operating temperature: 0. ..+40°C
- storage temperature: -20...+60°C
- operating humidity: max. 80% to 31°C decreasing linearly to 50% at 40°C
- operating altitude: max. 2000 m
Electrical safety:
- measurement category: III 600 V
- housing protection degree: IP40
Others:
- LCD display (liquid crystal), backlit, 3 ¾ digits (max. indication 4000)< /li>
- maximum wire diameter: 30 mm
- meter power supply: 9 V battery type 6LR61
- continuity test: I<0.5 mA, sound signal for R<50 Ω
- diode test: I=0.3mA, U0=1.5VDC
- over range indication: 'OL' is displayed
- frequency measurements: 2 readings per second
- input impedance: 10 MΩ (V DC and VAC)
- clamp size: opening approx. 30 mm (1.2”)
- auto-off after approximately 30 minutes