Multifunctional meter of electrical installation parameters MPI-530 WMPLMPI530

local index:
NPP032SONE
Catalog No:
WMPLMPI530
EAN code:
5907624021181
Manufacturer: SONEL
Level of security: IP54
Weight [g]: 2200
Dimensions [mm]: 288x223x75
Price:
2485,15 €
gross / pcs.
(including VAT 23%)
1129,61 € gross/kg.
Delivery in 3h
up to a week (working days)
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

Multifunction meterMPI-530of the newest generation that allows you to perform all measurements in an electrical installation in accordance with the PN-EN 61557 standard:

  • short-circuit loop impedance with a resolution of up to 0.001 Ω – accurate measurement also in circuits with RCDs,
  • parameters of RCDs,
  • insulation resistance,
  • earthing resistance,
  • continuity of protective and equipotential bonding.

The device has an innovative memory that allows saving tens of thousands of results in the structure of a ready protocol.

Data from the memory can be transmitted to a PC via a USB cable or wirelessly via Bluetooth®.

Fault loop impedance measurements:

  • short-circuit loop impedance measurement with a resolution of 0.001 Ω with a current of 23 A (44 A at phase-to-phase voltage) - short-circuit resistor Rzw = 10 Ω,
  • measuring voltage range: 95...440 V, frequency 45...65 Hz,
  • measurement of short-circuit loop impedance with resolution up to 0.01 Ω, in installations protected by RCDs with IΔn ≥ 30 mA without tripping,
  • automatic calculation of short-circuit current; distinguishing phase-to-phase voltage and phase-to-phase voltage,
  • measurements using UNI-Schuko plug with a button that triggers the measurement (also with L and N wires swapped) or 1.2 m, 5 m, 10 m, 20 m long wires with possible use of 3-phase socket adapters. (AGT),
  • selection of installation protections and automatic assessment of the measurement result.

Testing of AC, A, F, B and B+ RCDs:

  • measurement of ordinary, short-time delay and selective circuit breakers with rated residual currents of 10, 30, 100, 300, 500 and 1000 mA,
  • function of automatic measurement of a full set of circuit breaker parameters (after pressing the "START" button once, the meter performs the entire programmed cycle of measurements, including the possibility of measuring the impedance of the L-PE short-circuit loop with a current of 15 mA),
  • user-selectable shape of the forced leakage current waveform: sinusoidal (starting from the slope rising or falling), unidirectional pulsating (positive or negative), unidirectional pulsing with DC bias (positive and negative), constant (positive and negative),
  • measurement of IA trigger current with rising current,
  • measurement of tripping time tA at currents ½IΔn, 1IΔn, 2IΔn and 5IΔn ,
  • measurement of touch voltage UB and protective conductor resistance RE without tripping the circuit breaker,
  • detection of L and N conductors interchange in the socket; does not affect the performance of measurements,
  • the ability to measure the tripping current IA and the real tripping time tAI with one RCD trip,
  • measurements for the voltage 95...270 V.
  • < /ul>

    Insulation resistance measurements:

    • measurement voltages: 50 V, 100 V, 250 V, 500 V and 1000 V,
    • < < /li>
    • automatic discharge of the capacitance of the measured object after the measurement is completed,
    • acoustic determination of five-second time intervals to facilitate the capture of time characteristics during insulation resistance measurement.

    Low-voltage measurement of protective and equipotential bonding resistance:

    • measurement of protective conductor continuity with current ≥200 mA in two directions,
    • low current measurement with acoustic signaling,
    • auto-calibration of test leads - possibility to use test leads of any length.

    Earth resistance measurements:

    • technical method measurement

      Measurement of soil resistivity using the Wenner method.

      Measurement of illuminance.

      Quick check of correctness of PE protective conductor connection with using a touch electrode.

      Measurement and recording of voltage, frequency, alternating current, cosφ and power (active, reactive, apparent), voltage and current harmonics up to 40, THD coefficients.< /strong>

      Checking the motor phase sequence and rotation.

      Memory with a tree structure, dynamically managed (max. 10,000 results of each type of measurement) with the possibility of describing measurement points, objects, customer names.

      Electrical safety:

      • type insulation: double, according to PN-EN 61010-1 and IEC 61557
      • measurement category: IV 300 V (III 600 V)
      • degree of housing protection: IP54
      • < /ul>

Technical data

  • Level of security
    IP54
  • Dimensions [mm]
    288x223x75
  • Weight [g]
    2200