4P, 25A, 30mA residual current device CDC425J

Index local:
ARP223HAGE
Numéro de catalogue:
CDC425J
Code EAN:
3250611619512
Producteur: HAGER
Depth [mm]: 70
Number of modules: 4
Number of poles: 4
Bestsellers
Prix:
175,59 zł
gross / pcs.
(y compris la TVA 23%)
Prix le plus bas à partir de 30 jours avant la réduction: 377,61 zł gross -202,02 zł
Prix du fabricant: 408,36 zł gross
Accessible 1 pcs.
Ramassage en 1h
Quantité pcs.
(plusieurs:
1
)
Ajouter à la demande de devis
Ajouter au presse-papiers
Imprimer

Description du produit


The purpose of the residual current device is to protect people, animals and objects in direct or indirect contact with electricity. RCDs also provide fire protection because they monitor the condition of the insulation and disconnect the power supply when leakage currents occur. In the event of an earth fault, when the short-circuit current exceeds the sensitivity of the residual current device, the device automatically switches off the damaged part of the electrical installation within 0.2 seconds. It has an actuation indicator and an optical ON/OFF status indicator. Possibility of adding additional equipment. Ambient temperature from -25 to +40°C.

Données techniques

  • Depth [mm]
    70
  • Number of poles
    4
  • Rated insulation voltage [V]
    900
  • Rated current [A]
    25
  • Power dissipation [W]
    4.6
  • Height [mm]
    83
  • Number of modules
    4
  • PKWIU
    27.12.23.0
  • Number of modules
    4
  • Operating voltage [V]
    230/400
  • Differential current [mA]
    thirty
  • Level of security
    IP40
  • Width [mm]
    70
  • Short-circuit switching capacity [kA]
    6
  • Breakdown voltage [V]
    900

Autres données techniques

  • Number of poles
    4
  • Rated current
    25 A
  • Rated insulation voltage Ui
    500 V
  • Power loss
    4.5 W
  • Leakage current type
    AC
  • Short-time delayed tripping
    No
  • Surge current capacity
    0.25 kA
  • With interlocking device
    No
  • Additional equipment possible
    Yes
  • Width in number of modular spacings
    4
  • Ambient temperature during operating
    -25 ... 40 °C
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²
  • RAL-number (similar)
    7005
  • Rated voltage
    400 V
  • Rated fault current
    0.03 A
  • Rated impulse withstand voltage Uimp
    4 kV
  • Mounting method
    DIN rail
  • Selective protection
    No
  • Short-circuit breaking capacity (Icw)
    6 kA
  • Voltage type
    AC
  • Frequency
    50 Hz
  • Degree of protection (IP)
    IP20
  • Built-in depth
    70 mm
  • Pollution degree
    2
  • Connectable conductor cross section solid-core
    1 ... 25 mm²
  • Explosion-proof
    No

Détails du fabricant

Emballage en vrac

Une sorte de paquet Karton Pakiet Paleta Karton Pakiet Paleta
Quantité 1 pcs. 36 pcs. 864 pcs. 1 pcs. 36 pcs. 864 pcs.
poids (kg) 0,332 12,376 320,024 0,332 12,376 320,024
Largeur (m) 0,080 0,310 0,800 0,080 0,310 0,800
Longueur (m) 0,070 0,230 1,080 0,070 0,230 1,080
Profondeur (m) 0,090 0,360 1,200 0,090 0,360 1,200
Signaler une erreur