4P 40A 30mA RCD CDC440J

Index local:
ARP232HAGE
Numéro de catalogue:
CDC440J
Code EAN:
3250611619543
Producteur: HAGER
Depth [mm]: 70
Number of poles: 4
Rated insulation voltage [V]: 900
Bestsellers
Prix:
178,23 zł
gross / pcs.
(y compris la TVA 23%)
Prix le plus bas à partir de 30 jours avant la réduction: 377,61 zł gross -199,38 zł
Prix du fabricant: 396,06 zł gross
Livraison en 3h
Accessible 39 pcs.
Ramassage en 1h
Quantité pcs.
(plusieurs:
1
)
Ajouter à la demande de devis
Ajouter au presse-papiers
Imprimer

Description du produit


The task of the residual current device is to protect people, animals and objects in direct or indirect contact with electricity. Residual current devices also guarantee fire protection, as they monitor the condition of the insulation and disconnect the power supply when leakage currents occur. In the event of an earth fault, when the short-circuit current exceeds the sensitivity of the residual current device, the device automatically switches off the damaged part of the electrical installation within 0.2 seconds. It has a trip indicator and  optical ON/OFF status indicator. Possibility of adding additional equipment. Ambient temperature -25 to +40°C.

Données techniques

  • Depth [mm]
    70
  • Rated insulation voltage [V]
    900
  • Rated current [A]
    40
  • Width [mm]
    70
  • Short-circuit switching capacity [kA]
    6
  • PKWIU
    27.12.23.0
  • Number of poles
    4
  • Differential current [mA]
    thirty
  • Level of security
    IP40
  • Height [mm]
    83
  • Breakdown voltage [V]
    900

Autres données techniques

  • Number of poles
    4
  • Rated current
    40 A
  • Rated insulation voltage Ui
    500 V
  • Mounting method
    DIN rail
  • Selective protection
    No
  • Short-circuit breaking capacity (Icw)
    6 kA
  • With interlocking device
    No
  • Additional equipment possible
    Yes
  • Width in number of modular spacings
    4
  • Ambient temperature during operating
    -25 ... 40 °C
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²
  • Rated voltage
    400 V
  • Rated fault current
    30 A
  • Rated impulse withstand voltage Uimp
    4 kV
  • Leakage current type
    AC
  • Short-time delayed tripping
    No
  • Surge current capacity
    0.25 kA
  • Frequency
    50 Hz
  • Degree of protection (IP)
    IP20
  • Built-in depth
    70 mm
  • Pollution degree
    2
  • Connectable conductor cross section solid-core
    1 ... 25 mm²

Détails du fabricant

Emballage en vrac

Une sorte de paquet Karton Pakiet Paleta
Quantité 1 pcs. 36 pcs. 864 pcs.
poids (kg) 0,320 11,520 276,480
Largeur (m) 0,080 0,310 0,800
Longueur (m) 0,070 0,210 1,110
Profondeur (m) 0,090 0,360 1,200
Signaler une erreur