MCB Circuit breaker 50kA 2P C 16A HMX216

Místní index:
ABC064HAGE
Katalogové číslo.:
HMX216
EAN kód:
3250613231903
Výrobce: HAGER
Characteristic: c
Rated frequency [Hz]: 60
Depth [mm]: 70
Cena:
1129,80 zł
gross / kusů.
(včetně DPH 23%)
do 10 týdnů
Na zakázku
Množství kusů.
(vícenásobné:
1
)
Přidat do žádosti o cenovou nabídku
Přidat do schránky
Vytisknout

Popis produktu

MCB circuit breaker to protect the electrical installation against the effects of short circuits and overloads. It can also be used as a means of protection against electric shock - automatic shutdown in the event of a short-circuit with negligible impedance between the line conductor and the accessible conductive part or the protective conductor.

Technické údaje

  • Characteristic
    c
  • Depth [mm]
    70
  • Tightening torque [Nm]
    3.5 to 5
  • Rated current [A]
    16
  • Level of security
    IP20
  • power loss [W]
    7.23
  • Width [mm]
    53
  • Height [mm]
    90
  • Mechanical durability (number of cycles)
    20000
  • Rated switching voltage [V]
    415
  • Number of modules
    3
  • Ultimate short-circuit breaking capacity Icu for 230V [kA]
    50
  • Ultimate short-circuit breaking capacity Icu for 400V [kA]
    50
  • Ultimate short-circuit breaking capacity per pole for 400V [kA]
    4.5
  • storage temperature [°C]
    from -25 to 80
  • Rated current correction factor for 2 devices installed side by side
    1
  • Rated surge voltage [V]
    6000
  • Wire cross-section (cord) [mm²]
    1.5 - 35
  • PKWIU
    27.12.23.0
  • Rated frequency [Hz]
    60
  • Number of poles
    2
  • Rated insulation voltage [V]
    500
  • Family
    MCB
  • Power dissipation [W]
    3.5
  • Power loss per pole [W]
    3.6
  • Connection type
    Clamps with alignment system
  • Electrical endurance (number of cycles)
    4000
  • Operating temperature range [°C]
    from -5 to 60
  • Rated short-circuit breaking capacity Icn [kA]
    50
  • Max/min value of the AC current of the protection activation
    7.9/11.9 in
  • Ultimate short-circuit breaking capacity Icu for 240V [kA]
    50
  • Ultimate short-circuit breaking capacity Icu for 415V [kA]
    50
  • Service short-circuit breaking capacity Ics [%]
    50
  • Supply voltage type
    AC
  • Rated current correction factor for 3 devices installed side by side
    0.95
  • Number of protected poles
    2
  • Conductor cross-section (wire) [mm²]
    1.5 - 50

Další technické údaje

  • Built-in depth
    70 mm
  • Number of poles (total)
    2
  • Rated current
    16 A
  • Rated insulation voltage Ui
    500 V
  • Voltage type
    AC
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
    50 kA
  • Current limiting class
    3
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 50 mm²
  • Release characteristic
    C
  • Number of protected poles
    2
  • Rated voltage
    415 V
  • Rated impulse withstand voltage Uimp
    6 kV
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
    50 kA
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    No
  • Pollution degree
    3
  • Width in number of modular spacings
    3
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 70 mm²

Podrobnosti o výrobci

Velkoobjemová balení

Typ obalu Karton Pakiet Paleta Karton Pakiet Paleta
Množství 1 kusů. 24 kusů. 576 kusů. 1 kusů. 24 kusů. 576 kusů.
Hmotnost (kg) 0,370 8,970 215,420 0,370 8,970 215,420
Šířka (m) 0,080 0,310 0,800 0,080 0,310 0,800
Délka (m) 0,050 0,110 1,050 0,050 0,110 1,050
Hloubka (m) 0,090 0,360 1,200 0,090 0,360 1,200
Nahlásit chybu