RCD 25A 300mA 2pole AC type CFC225J

local index:
ARP068HAGE
Catalog No:
CFC225J
EAN code:
3250611619673
Manufacturer: HAGER
Depth [mm]: 70
Number of poles: 2
Differential current [mA]: 300
Price:
52,29 €
gross / pcs.
(including VAT 23%)
Delivery in 3h
up to 4 weeks (business days)
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

Residual current circuit breakers Type AC
• residual current circuit breakers with high and medium sensitivity, AC residual currents (alternating sinusoidal current),
• rated operational voltage: 230/400 V AC - two-pole circuit breaker, 400 V AC - four-pole circuit breaker,
• rated operating differential current in the range from 10 mA to 500 mA,
• rated making and breaking capacity (Im): 1500 A,
• rated short-circuit current (Inc): the value depends on the rated current of the short-circuit protection protecting the residual current circuit breaker,
• optical actuation indicator (circuit breaker opening/closing and circuit breaker tripping due to differential current),
• wide range of accessoriesó
• possibility of connection using vertical and horizontal comb busbars,
• cage terminals:
- circuit breakers with a rated current of 16 ÷ 63 A: solid up to 25 mm2, stranded up to 16 mm2
- circuit breakers with a rated current of 80 ÷ 125 A: solid up to 50 mm2, stranded up to 35 mm2,
• degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.

Technical data

  • Depth [mm]
    70
  • Differential current [mA]
    300
  • Power dissipation [W]
    1
  • Trigger type
    AC
  • PKWIU
    27.12.23.0
  • Number of poles
    2
  • Rated current [A]
    25
  • Width [mm]
    35
  • Height [mm]
    83

Other technical data

  • Number of poles
    2
  • Rated current
    25 A
  • Rated insulation voltage Ui
    500 V
  • Mounting method
    DIN rail
  • Selective protection
    No
  • Short-circuit breaking capacity (Icw)
    6 kA
  • With interlocking device
    No
  • Additional equipment possible
    Yes
  • Width in number of modular spacings
    2
  • Ambient temperature during operating
    -25 ... 40 °C
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²
  • Rated voltage
    230 V
  • Rated fault current
    300 A
  • Rated impulse withstand voltage Uimp
    4 kV
  • Leakage current type
    AC
  • Short-time delayed tripping
    No
  • Surge current capacity
    0.25 kA
  • Frequency
    50 Hz
  • Degree of protection (IP)
    IP20
  • Built-in depth
    70 mm
  • Pollution degree
    2
  • Connectable conductor cross section solid-core
    1 ... 25 mm²

Bulk packaging

A kind of package Karton Pakiet Paleta
Quantity 1 pcs. 1 pcs. 60 pcs. 1440 pcs.
Weight (kg) 0,180 0,195 12,060 322,120
Width (m) 0,035 0,080 0,321 0,800
Length (m) 0,085 0,038 0,219 1,026
Depth (m) 0,073 0,099 0,370 1,200