Miniature circuit breaker 6kA B four-pole 63A MBN463E

local index:
ARB003HAGE
Catalog No:
MBN463E
EAN code:
3250614313271
Manufacturer: HAGER
Characteristic: b
Depth [mm]: 70
Number of modules: 4
Price:
74,34 €
gross / pcs.
(including VAT 23%)
Delivery in 3h
up to 4 weeks (business days)
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

Current circuit breakers 0.5 - 50 A. Type B Rated short-circuit breaking capacity 6000 A
• rated short-circuit switching capacity: 6000 A, in accordance with PN-EN 60898-1,
• energy limitation class: 3,
• rated operational voltage: 230/400 V AC - single-pole circuit breaker, 400 V AC - multi-pole circuit breaker,
• can be used in DC circuits,
• wide range of accessoriesó
• possibility of connection using vertical and horizontal comb busbars,
• cage terminals: wire up to 25 mm2, strand up to 16 mm2,
• description field with a safety flap,
• degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.

Technical data

  • Characteristic
    b
  • Number of modules
    4
  • Rated voltage [V]
    230
  • Rated current [A]
    63
  • Width [mm]
    70
  • Rated short-circuit breaking capacity [kA]
    6
  • PKWIU
    27.12.22.0
  • Depth [mm]
    70
  • Number of poles
    4
  • Rated insulation voltage [V]
    500
  • Power dissipation [W]
    25.6
  • Height [mm]
    83
  • Number of modules
    4

Other technical data

  • Built-in depth
    70 mm
  • Number of poles (total)
    4
  • Rated current
    63 A
  • Rated insulation voltage Ui
    500 V
  • Voltage type
    AC
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
    10 kA
  • Current limiting class
    3
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 25 mm²
  • Release characteristic
    B
  • Number of protected poles
    4
  • Rated voltage
    400 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
    6 kA
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    No
  • Pollution degree
    2
  • Width in number of modular spacings
    4
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 35 mm²

Bulk packaging

A kind of package Karton Pakiet Paleta
Quantity 1 pcs. 3 pcs. 36 pcs. 864 pcs.
Weight (kg) 0,488 1,566 19,232 484,568
Width (m) 0,070 0,097 0,315 0,800
Length (m) 0,087 0,082 0,230 1,070
Depth (m) 0,073 0,227 0,360 1,200