MCB Circuit Breaker 6kA 4 Pole 4A Characteristic C MCN404E

Indeks lokalny:
ABC196HAGE
Nr katalogowy:
MCN404E
Kod EAN:
3250614333835
Producent: HAGER
Characteristic: c
Rated frequency [Hz]: 60
Depth [mm]: 70
Cena:
64,91 €
gross / szt.
(w tym VAT 23%)
Dostawa do 3h
do 10 tygodni (dni robocze)
Odbiór za 1h
Ilość szt.
(wielokrotność:
1
)
Dodaj do schowka
Drukuj

Opis produktu

MCB circuit breaker to protect the electrical installation against the effects of short circuits and overloads. It can also be used as a means of protection against electric shock - automatic shutdown in the event of a short-circuit with negligible impedance between a line conductor and an accessible conductive part or a protective conductor.

Dane techniczne

  • Characteristic
    c
  • Depth [mm]
    70
  • Tightening torque [Nm]
    2.8
  • Rated current [A]
    4
  • Level of security
    IP20
  • power loss [W]
    7.7
  • Width [mm]
    70
  • Height [mm]
    83
  • Mechanical durability (number of cycles)
    20000
  • Rated short-circuit breaking capacity [kA]
    6
  • Rated short-circuit breaking capacity Icn [kA]
    6
  • Max/min value of the AC current of the protection activation
    5/10 In
  • Ultimate short-circuit breaking capacity per pole for 400V [kA]
    3
  • Rated current at 30°C [A]
    4
  • Rated current at 45°C [A]
    3.7
  • Rated current at 55°C [A]
    3.5
  • Rated current at 65°C [A]
    3.3
  • Operating short-circuit breaking current Ics [kA]
    6
  • Supply voltage type
    AC
  • Rated current correction factor for 3 devices installed side by side
    0.95
  • Number of protected poles
    4
  • Rated frequency [Hz]
    60
  • Number of poles
    4
  • Rated insulation voltage [V]
    500
  • Family
    MCB
  • Power dissipation [W]
    3
  • Power loss per pole [W]
    2
  • Connection type
    With a screw
  • Electrical endurance (number of cycles)
    4000
  • Operating temperature range [°C]
    from -25 to 60
  • Rated switching voltage [V]
    230/400
  • Number of modules
    4
  • Ultimate short-circuit breaking capacity Icu for 415V [kA]
    10
  • Rated current at 20°C [A]
    4.2
  • Rated current at 40°C [A]
    3.8
  • Rated current at 50°C [A]
    3.6
  • Rated current at 60°C [A]
    3.4
  • Rated current at 70°C [A]
    3.2
  • storage temperature [°C]
    from -25 to 80
  • Rated current correction factor for 2 devices installed side by side
    1
  • Rated surge voltage [V]
    4000
  • PKWIU
    27.12.22.0

Pozostałe dane techniczne

  • Built-in depth
    70 mm
  • Number of poles (total)
    4
  • Rated current
    4 A
  • Rated insulation voltage Ui
    500 V
  • Voltage type
    AC
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
    10 kA
  • Current limiting class
    3
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 25 mm²
  • Release characteristic
    C
  • Number of protected poles
    4
  • Rated voltage
    400 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
    6 kA
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    No
  • Pollution degree
    2
  • Width in number of modular spacings
    4
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 35 mm²

Dane producenta

  • Producent
    HAGER POLO Sp. z o. o.
  • Adres
    43-100 Tychy Fabryczna 10
  • NIP
    6460015532

Opakowania zbiorcze

Rodzaj opakowania Karton Pakiet Paleta Karton Pakiet Paleta
Ilość 3 szt. 36 szt. 864 szt. 3 szt. 36 szt. 864 szt.
Waga (kg) 1,465 17,975 454,400 1,465 17,975 454,400
Szerokość (m) 0,100 0,315 0,800 0,100 0,315 0,800
Długość (m) 0,080 0,240 1,050 0,080 0,240 1,050
Głębokość (m) 0,225 0,360 1,200 0,225 0,360 1,200

Pliki do pobrania

Zgłoś błąd