MCB Circuit Breaker 6kA 4 Pole 13A Characteristic B MBN413E

local index:
ABB072HAGE
Catalog No:
MBN413E
EAN code:
3250614313202
Manufacturer: HAGER
Characteristic: b
Rated frequency [Hz]: 60
Depth [mm]: 70
Price:
38,08 €
gross / pcs.
(including VAT 23%)
Delivery in 3h
up to 10 weeks (business days)
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

MCB circuit breaker to protect the electrical installation against the effects of short circuits and overloads. It can also be used as a means of protection against electric shock - automatic shutdown in the event of a short-circuit with negligible impedance between the line conductor and the accessible conductive part or the protective conductor.

Technical data

  • Characteristic
    b
  • Depth [mm]
    70
  • Tightening torque [Nm]
    2.8
  • Rated current [A]
    13
  • Level of security
    IP20
  • power loss [W]
    9.1
  • Width [mm]
    70
  • Height [mm]
    83
  • Mechanical durability (number of cycles)
    20000
  • Rated short-circuit breaking capacity [kA]
    6
  • Rated short-circuit breaking capacity Icn [kA]
    6
  • Max/min value of the AC current of the protection activation
    3/5 In
  • Ultimate short-circuit breaking capacity per pole for 400V [kA]
    3
  • Rated current at 30°C [A]
    13
  • Rated current at 45°C [A]
    12
  • Rated current at 55°C [A]
    11.3
  • Rated current at 65°C [A]
    10.6
  • Operating short-circuit breaking current Ics [kA]
    6
  • Supply voltage type
    AC
  • Rated current correction factor for 3 devices installed side by side
    0.95
  • Number of protected poles
    4
  • Rated frequency [Hz]
    60
  • Number of poles
    4
  • Rated insulation voltage [V]
    500
  • Family
    MCB
  • Power dissipation [W]
    3.5
  • Power loss per pole [W]
    2.3
  • Connection type
    With a screw
  • Electrical endurance (number of cycles)
    4000
  • Operating temperature range [°C]
    from -25 to 60
  • Rated switching voltage [V]
    230/400
  • Number of modules
    4
  • Ultimate short-circuit breaking capacity Icu for 415V [kA]
    10
  • Rated current at 20°C [A]
    13.6
  • Rated current at 40°C [A]
    12.4
  • Rated current at 50°C [A]
    11.7
  • Rated current at 60°C [A]
    11
  • Rated current at 70°C [A]
    10.2
  • storage temperature [°C]
    from -25 to 80
  • Rated current correction factor for 2 devices installed side by side
    1
  • Rated surge voltage [V]
    4000
  • PKWIU
    27.12.22.0

Other technical data

  • Built-in depth
    70 mm
  • Number of poles (total)
    4
  • Rated current
    13 A
  • Rated insulation voltage Ui
    500 V
  • Voltage type
    AC
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
    10 kA
  • Current limiting class
    3
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 25 mm²
  • Release characteristic
    B
  • Number of protected poles
    4
  • Rated voltage
    400 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
    6 kA
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    No
  • Pollution degree
    2
  • Width in number of modular spacings
    4
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 35 mm²

Manufacturer details

  • Manufacturer
    HAGER POLO Sp. z o. o.
  • Address
    43-100 Tychy Fabryczna 10
  • Tax identification number
    6460015532

Bulk packaging

A kind of package Karton Pakiet Paleta Karton Pakiet Paleta
Quantity 3 pcs. 36 pcs. 330 pcs. 3 pcs. 36 pcs. 330 pcs.
Weight (kg) 1,220 14,990 4969,700 1,220 14,990 4969,700
Width (m) 0,105 0,325 0,800 0,105 0,325 0,800
Length (m) 0,080 0,230 1,050 0,080 0,230 1,050
Depth (m) 0,225 0,360 1,200 0,225 0,360 1,200

Files to download

Report an error