MCB Circuit breaker 10kA 1+N 6A characteristic C NCN506

Indeks lokalny:
ABC101HAGE
Nr katalogowy:
NCN506
Kod EAN:
3250614615191
Producent: HAGER
Characteristic: c
Depth [mm]: 70
Number of poles: 2
Cena:
46,57 €
gross / szt.
(w tym VAT 23%)
Dostawa do 3h
do 10 tygodni (dni robocze)
Odbiór za 1h
Ilość szt.
(wielokrotność:
1
)
Dodaj do schowka
Drukuj

Opis produktu

MCB circuit breaker to protect the electrical installation against the effects of short circuits and overloads. It can also be used as a means of protection against electric shock - automatic shutdown in the event of a short-circuit with negligible impedance between the line conductor and the accessible conductive part or the protective conductor.

Dane techniczne

  • Characteristic
    c
  • Number of poles
    2
  • Rated insulation voltage [V]
    500
  • Family
    MCB
  • Power dissipation [W]
    3
  • Power loss per pole [W]
    1.34
  • Height [mm]
    83
  • Mechanical durability (number of cycles)
    20000
  • Rated switching voltage [V]
    240
  • Number of modules
    2
  • Max/min value of the AC current of the protection activation
    5/10 In
  • Input terminal capacitance (wire) [mm²]
    1/35
  • Output terminal capacitance (wire) [mm²]
    1/35
  • Ultimate short-circuit breaking capacity Icu for 240V [kA]
    15
  • Rated current at 30°C [A]
    6
  • Rated current at 45°C [A]
    5.52
  • Rated current at 55°C [A]
    5.17
  • Rated current at 65°C [A]
    4.8
  • storage temperature [°C]
    from -25 to 80
  • Rated current correction factor for 2 devices installed side by side
    1
  • Rated surge voltage [V]
    6000
  • PKWIU
    27.12.22.0
  • Depth [mm]
    70
  • Tightening torque [Nm]
    2.8
  • Rated current [A]
    6
  • Level of security
    IP20
  • power loss [W]
    2.68
  • Width [mm]
    35
  • Electrical endurance (number of cycles)
    4000
  • Operating temperature range [°C]
    from -25 to 60
  • Short-circuit breaking capacity [kA]
    10
  • Maximum operating voltage [V]
    253
  • Input terminal capacity (cord) [mm²]
    1/25
  • Output terminal capacity (cord) [mm²]
    1/25
  • Ultimate short-circuit breaking capacity Icu for 230V [kA]
    15
  • Rated current at 20°C [A]
    6.3
  • Rated current at 40°C [A]
    5.68
  • Rated current at 50°C [A]
    5.35
  • Rated current at 60°C [A]
    4.99
  • Rated current at 70°C [A]
    4.6
  • Supply voltage type
    AC
  • Rated current correction factor for 3 devices installed side by side
    0.95
  • Number of protected poles
    1

Pozostałe dane techniczne

  • Built-in depth
    70 mm
  • Number of poles (total)
    2
  • Rated current
    6 A
  • Rated insulation voltage Ui
    500 V
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
    10 kA
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
    15 kA
  • Current limiting class
    3
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 25 mm²
  • Release characteristic
    C
  • Number of protected poles
    1
  • Rated voltage
    230 V
  • Rated impulse withstand voltage Uimp
    6 kV
  • Voltage type
    AC
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    Yes
  • Pollution degree
    2
  • Width in number of modular spacings
    2
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 35 mm²

Dane producenta

  • Producent
    HAGER POLO Sp. z o. o.
  • Adres
    43-100 Tychy Fabryczna 10
  • NIP
    6460015532

Opakowania zbiorcze

Rodzaj opakowania Karton Pakiet Paleta Karton Pakiet Paleta
Ilość 6 szt. 72 szt. 1728 szt. 6 szt. 72 szt. 1728 szt.
Waga (kg) 1,378 16,443 417,632 1,378 16,443 417,632
Szerokość (m) 0,097 0,323 0,800 0,097 0,323 0,800
Długość (m) 0,082 0,247 1,138 0,082 0,247 1,138
Głębokość (m) 0,228 0,376 1,200 0,228 0,376 1,200

Pliki do pobrania

Zgłoś błąd