Circuit breaker MCB 15kA 4P B 80A HMB480

local index:
ABB006HAGE
Catalog No:
HMB480
EAN code:
3250613230104
Manufacturer: HAGER
Rated frequency [Hz]: 50/60
Depth [mm]: 70
Number of poles: 4
Price:
290,71 €
gross / pcs.
(including VAT 23%)
Delivery in 3h
up to 10 weeks (business days)
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

Current circuit breakers 80 - 125 A, type B, C and D
Rated short-circuit breaking capacity 15000 A:
• rated short-circuit switching capacity (Icn): 15000 A, in accordance with PN-EN 60898-1
• rated ultimate short-circuit breaking capacity (Icu): 15 kA, in accordance with PN-EN 60947-2
• low power loss [W]
• the open state is indicated by a green marker above the lever
• cage clamps: wire up to 70 mm², rope up to 35 mm²
• the possibility of using residual current blocks

Technical data

  • Rated frequency [Hz]
    50/60
  • Number of poles
    4
  • Connection
    Clamps with alignment system
  • power loss [W]
    25.7
  • Type
    b
  • Electrical endurance (number of cycles)
    4000
  • Rated short-circuit breaking capacity [kA]
    15
  • PKWIU
    27.12.22.0
  • Depth [mm]
    70
  • Rated insulation voltage [V]
    500
  • Rated current [A]
    80
  • Width [mm]
    106
  • Height [mm]
    90
  • Mechanical durability (number of cycles)
    20000
  • Number of modules
    6

Other technical data

  • Built-in depth
    70 mm
  • Number of poles (total)
    4
  • Rated current
    80 A
  • Rated insulation voltage Ui
    500 V
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
    15 kA
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
    15 kA
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
    15 kA
  • Concurrently switching neutral conductor
    No
  • Pollution degree
    3
  • Width in number of modular spacings
    6
  • Ambient temperature during operating
    -25 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 70 mm²
  • Release characteristic
    B
  • Number of protected poles
    4
  • Rated voltage
    415 V
  • Rated impulse withstand voltage Uimp
    6 kV
  • Voltage type
    AC
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
    15 kA
  • Frequency
    50 ... 60 Hz
  • Over voltage category
    3
  • Additional equipment possible
    Yes
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 50 mm²

Manufacturer details

Bulk packaging

A kind of package Karton Pakiet Paleta
Quantity 1 pcs. 1 pcs. 12 pcs. 504 pcs.
Weight (kg) 0,950 0,950 11,600 510,200
Width (m) 0,106 0,095 0,315 0,800
Length (m) 0,090 0,085 0,125 0,759
Depth (m) 0,072 0,120 0,365 1,200