Circuit breaker iC60N 1P, 10A A9F04110

local index:
ABC050SCHN
Catalog No:
A9F04110
EAN code:
3606480440342
Manufacturer: SCHNEIDER ELECTRIC
Characteristic: c
Number of poles: 1
Rated current [A]: 10
Price:
6,24 €
gross / pcs.
(including VAT 23%)
Delivery in 3h
Accessible 50 pcs.
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to clipboard
Print

Product description

Schneider Electric's iC60N series overcurrent circuit breakers provide protection against short circuits and overloads, while providing convenient installation in a switchboard (tool-free installation on a DIN rail, double terminals up/down), safety of service (VisiSafe indicator - confirmation of circuit breaker contact opening, plugs terminals when tightening the wires) as well as the ability to communicate via the Smartlink system using an auxiliary contact confirming the status of the circuit breaker and the cause of tripping.

Advantages:

  • Efficiency you deserve
  • New quality in final power distribution
  • Full safety of circuit protection with VisiSafe
  • Increased power continuity with VisiTrip
  • Ease of selection thanks to logical catalog numbering
  • Easy to install with ergonomic and safe terminal covers (IP20B) and strong connections (twice as much pressure as standard tightening torque)
  • Environmentally friendly with 100% materials % recoverable and recyclable.

Application:

  • Low-voltage energy final distribution
  • Electrical circuit protection in industrial and general construction
  • All applications, especially in polluted environments and networks
  • Protection of motor circuits
  • Protection of DC circuits.
Possibility of direct connection of two wires with different cross-sections. Optical Visi-Trip electrical trip indicator, white/red. Possibility of disassembly of a single device without the need to remove the connecting rail. Removable from DIN rail without tools.

Technical data

  • Characteristic
    c
  • Rated current [A]
    10
  • Number of poles
    1
  • PKWIU
    27.12.22.0

Other technical data

  • Release characteristic
    C
  • Number of protected poles
    1
  • Rated voltage
    230 V
  • Rated impulse withstand voltage Uimp
    6 kV
  • Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
    10 kA
  • Frequency
    50 ... 60 Hz
  • Concurrently switching neutral conductor
    No
  • Pollution degree
    3
  • Width in number of modular spacings
    1
  • Degree of protection (IP)
    IP20
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²
  • Number of poles (total)
    1
  • Rated current
    10 A
  • Rated insulation voltage Ui
    500 V
  • Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
    6 kA
  • Voltage type
    AC/DC
  • Current limiting class
    3
  • Over voltage category
    4
  • Additional equipment possible
    Yes
  • Built-in depth
    44.5 mm
  • Ambient temperature during operating
    -35 ... 70 °C
  • Connectable conductor cross section solid-core
    1 ... 25 mm²