Residual current circuit breakers Type AC

• residual current circuit breakers with high and medium sensitivity, AC residual currents (sinusoidal alternating current),

• rated switching voltage: 230/400 V AC - two-pole circuit breaker, 400 V AC - four-pole circuit breaker,

• rated operating differential current in the range from 10 mA to 500 mA,

• rated making and breaking capacity (Im): 1500 A,

• rated conventional short-circuit current (Inc): the value depends on the rated current of the short-circuit protection protecting the residual current circuit breaker,

• optical actuation indicator (circuit breaker opening/closing and circuit breaker tripping due to differential current),

• a wide range of accessories

• possibility of connection using vertical and horizontal comb busbars,

• cage clamps:

   - circuit breakers with a rated current of 16 ÷ 63 A: solid up to 25 mm2, stranded up to 16 mm2

   - circuit breakers with a rated current of 80 ÷ 125 A: solid up to 50 mm2, stranded up to 35 mm2

• degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.

Technical data

  • Depth [mm]
    70
  • Number of poles
    2
  • Differential current [mA]
    thirty
  • Power dissipation [W]
    6.3
  • Height [mm]
    83
  • Breakdown voltage [V]
    500
  • Number of modules
    2
  • Rated insulation voltage [V]
    500
  • Rated current [A]
    40
  • Width [mm]
    35
  • Number of modules
    2
  • PKWIU
    27.12.23.0

Other technical data

  • Number of poles
    2
  • Rated current
    40 A
  • Rated insulation voltage Ui
    500 V
  • Mounting method
    DIN rail
  • Selective protection
    No
  • Short-circuit breaking capacity (Icw)
    6 kA
  • With interlocking device
    Yes
  • Additional equipment possible
    Yes
  • Width in number of modular spacings
    2
  • Ambient temperature during operating
    -25 ... 40 °C
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²
  • Rated voltage
    230 V
  • Rated fault current
    30 A
  • Rated impulse withstand voltage Uimp
    4 kV
  • Leakage current type
    AC
  • Short-time delayed tripping
    No
  • Surge current capacity
    0.25 kA
  • Frequency
    50 Hz
  • Degree of protection (IP)
    IP20
  • Built-in depth
    70 mm
  • Pollution degree
    2
  • Connectable conductor cross section solid-core
    1 ... 25 mm²

Manufacturer details

Bulk packaging

A kind of package Karton Pakiet Paleta Karton Pakiet Paleta
Quantity 1 pcs. 60 pcs. 1440 pcs. 1 pcs. 60 pcs. 1440 pcs.
Weight (kg) 0,180 11,160 267,830 0,180 11,160 267,830
Width (m) 0,080 0,310 0,800 0,080 0,310 0,800
Length (m) 0,040 0,210 0,990 0,040 0,210 0,990
Depth (m) 0,100 0,350 1,200 0,100 0,350 1,200
Report an error