Multifunctional meter of electrical installation parameters

Great little multitasker

Multifunctional meter of electrical installation parameters Sonel MPI-506 is a unique model of a handheld meter used to perform precise measurements of electrical installation parameters. In its neat and small dimensions, the meter hides a wealth of measurement functions. An additional advantage of this device is its extremely handy and ergonomic form, which facilitates carrying and increases the comfort of work.

The Sonel MPI-506 meter is one of the smallest multifunctional measuring instruments on the market, it surprises with intuitive operation and extensive capabilities. It is a versatile device that is ready to work in all conditions. Developed for specialists in the installation and electrical industries, as well as for professional measuring technicians.

With this instrument, it is possible to perform basic measurements of various types, including the measurement of parameters in the short-circuit loop, insulation resistance, measurement of the resistance of protective and equipotential bonding connections, as well as testing residual current circuit breakers AC and A type. Due to its compact form and favorable price, the meter will appeal especially to novice users. The excellent precision of work makes its advantages also appreciated by advanced measuring technicians.

Features

  • Measurement of parameters in the fault loop
    • Fault loop impedance measurement in networks with rated voltages: 220/380 V, 230/400 V, 240/415 V with frequencies of 45...65 Hz, operating voltage range: 180...460  V
    • Indication of short-circuit loop resistance R and short-circuit loop reactance X
    • Measurement of short-circuit loop impedance with 15 mA current without tripping RCD circuit breakers
    • Maximum measuring current: 7.6A (at 230V), 13.3A (at 400V)
  • Testing of residual current circuit breakers type AC, A
    • Measurement of instantaneous, short delay and selective residual current circuit breakers with rated residual currents of 10, 15, 30, 100, 300, 500 mA
    • Measurement of tripping current IA and tripping time tA for currents 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn
    • RE and UB measurement without RCD tripping
    • Extended AUTO function of RCD measurement, with the possibility of measuring ZL-PE with low current
    • IA and tA measurement with one RCD tripping
  • Insulation resistance measurement
    • Test voltages 100 V, 250 V, 500 V
  • Resistance measurement of protective and equalizing connections
    • Measurement of the continuity of protective connections with ±200 mA current in accordance with the PN-EN 61557-4 standard
    • Autocalibration of test leads - any leads can be used
    • Low current resistance measurement
  • Indication of phase sequence

Additional Features

  • Checking the correct connection of the PE wire using a touch electrode.
  • Measurement of voltage (0...500 V) and mains frequency.
  • Memory 990 results.
  • Wireless data transmission to a computer.
  • Illuminated buttons.

Simplicity and sophistication

Probably the world's smallest meter with so many measurement functions. Their selection is carried out using a rotary switch. Additional parameters are set with buttons located on the front of the housing. The settings are remembered by the device even when the battery is completely discharged. All buttons are backlit, as is the segment display, making it easy to use in low light. Extensive memory eliminates the need to keep notes during measurements.

Installation security check

With the instrument, you can control home and industrial electrical installations in terms of safety. Its advantage is quick measurement (several seconds!) of short-circuit loop impedance in circuits with RCDs.

Research can be easily automated by:

  • testing of RCDs in Auto mode,
  • using the WS type adapter to test the installation through a standard 230 V socket.

Increased resistance to environmental conditions

The meter will cope well in harsh environmental conditions. Protection against dust and water ingress is provided by a casing with an IP67 tightness level.

Communications and software

You can transfer measurement data to a computer using Bluetooth wireless communication. In order to generate a test report in the field of electric shock protection, use the Sonel Electrical Measurements program. Saving the downloaded resources to the simplest formats and printing is provided by Sonel Reader.

 

Measurement functions Measurement range Display range Resolution Accuracy
Fault loop impedance        
ZL-PE, ZL-N, ZL-L short-circuit loop 0.13 Ω…1999 Ω according to IEC 61557 0.00 Ω…1999 Ω from 0.01 Ω ±(5% m.v. + 3 digits)
ZL-PE short-circuit loop in RCD mode since 0.5 Ω…1999 Ω according to IEC 61557 0.00 Ω…1999 Ω from 0.01 Ω from ±(6% m.v. + 5 digits)
Measurements of RCD Parameters        
RCD tripping test and tripping time measurement tA measuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn        
RCD of general type and short delay 0 ms…300 ms 0 ms…300 ms 1 ms ±(2% m.v. + 2 digits)
Selective RCD 0 ms…500 ms 0 ms…500 ms 1 ms ±(2% m.v. + 2 digits)
Measurement of RCD tripping current IA measuring current 0.3 IΔn…2.0 IΔn        
for sinusoidal residual current (AC type) 3.0mA…500mA 3.0mA…500mA from 0.1mA ±5% IΔn
for 1-way and 1-way differential current with 6 mA dc bias (type A) 3.5mA…420mA 3.5mA…420mA from 0.1mA ±10% IΔn
Insulation resistance        
Measuring voltage 100V 100kΩ…99.9MΩ according to IEC 61557-2 0 kΩ…99.9 MΩ from 1kΩ ±(5% m.v. + 8 digits)
Test voltage 250V 250kΩ…199.9MΩ according to IEC 61557-2 0 kΩ…199.9 MΩ from 1kΩ ±(5% m.v. + 8 digits)
Measuring voltage 500 V 500kΩ…599.9MΩ according to IEC 61557-2 0 kΩ…599.9 MΩ from 1kΩ ±(5% m.v. + 8 digits)
Resistance of protective and equipotential wires        
Continuity measurement of protective and equipotential bonding with ±200 mA 0.12 Ω…400 Ω according to IEC 61557-4 0.00 Ω…400 Ω from 0.01 Ω ±(2% m.v. + 3 digits)
Low current resistance measurement 0.0 Ω…1999 Ω 0.0 Ω…1999 Ω from 0.1 Ω ±(3% m.v. + 3 digits)
Phase sequence indication positive, negative, UL-L voltage: 100 V…440 V (45 Hz…65 Hz)      

 

Program for creating protocols from installation security tests

The latest version of the popular program for creating protocols from electrical measurements. PE6 simplifies the documentation process. It minimizes its time. It automates. All thanks to numerous built-in mechanisms, tools and functions.

Program features:

  • compliance of the printed protocol with the new standards PN-HD 60364-6:2016-07, PN-HD 60364-4-41:2017-09
  • cooperation with SONEL S.A. meters,
  • tree structure of the document,
  • extensive databases of security and measuring points,
  • automatic calculation of required values,
  • automatic evaluation of measured results,
  • measurement schedule,
  • inserting photos and drawings to protocols,
  • printing measurement controls and table descriptive labels,
  • calculation of performed measurements,
  • printing invoices,
  • automatically populating protocols with a series of data.

The program supports the creation of documentation after tests in the field of comprehensive control of measurement points and:

  • trip efficiency (TN-S, TN-C, TN-C-S, TT, IT),
  • parameterów of RCD's,
  • circuit insulation status (TN-S, TN-C, TN-C-S, TT, IT),
  • the condition of insulation of electric cables,
  • the condition of the lightning protection system and earthing,
  • wire continuity,
  • insulation resistance of short-circuited and open-circuit motors,
  • resistance of contactors,
  • resistance of circuit breakers,
  • transformer devices.

Hardware requirements:

  • Operating system: Windows 10
  • Minimum resolution: 1024x768
  • Recommended resolution: 1920x1080

Technical data

  • Model
    MPI-506

Manufacturer details

  • Manufacturer
    SONEL S.A.
  • Address
    58-100 ŚWIDNICA Armii Krajowej 29
  • Tax identification number
    8840033448