Rainwater level control relay 230V 16A 35mm PZ-828RC-WD

Índice local:
API144FIFQ
Número de catálogo:
PZ-828RC-WD
Código EAN:
5902431676036
Fabricante: F&F
Installation: On the TH-35 rail
Rated voltage [V]: 230
Power consumption [W]: 1.1
Precio:
245,61 zł
gross / uds.
(IVA incluido 23%)
Entrega en 3h
Accesible 21 uds.
Recogida en 1h
Cantidad uds.
(múltiple:
1
)
Añadir a solicitud de presupuesto
Añadir al portapapeles
Imprimir

Descripción del producto

Liquid level control relay

  • for rainwater level control
  • with regulation sensitivity by the user,
  • single-state,
  • complete with PZ probe.< /strong>

Detects electrically conductive liquids at the level of the flood probe installation.

How does the rainwater level control relay work?
In a dry condition, the relay contact remains in position 7-4. When the probe is flooded with liquid (i.e. the probe electrodes are short-circuited), the relay contact is switched to position 7-8. After the liquid level drops (opening of the probe electrodes), the relay contact returns to position 7-4.
 

Method of connecting the probe
The design of the probe allows it to be mounted on a flat, horizontal surface, e.g. on the floor in a room with hydro valves, flow pipes or in a laundry room. Thanks to this, it is possible to quickly detect a failure (flooding the room with liquid) while switching off electrical circuits or activating sound or light signals (alarm).< br />
The probe cable can be extended to 100 m.

Up to 10 probes can be connected to input 5-6 - in series or in parallel:

  • in series - for a dependent fluid level control system in many points - all connected sensors must be shorted simultaneously for the relay to operate
  • parallel - for an alternative fluid level control system in many points points - at least one of the connected sensors must be short-circuited. When connected in series, the sensitivity of the sensors decreases (conductivity decreases).
     

Attention!
Terminals 5- 6 are separated from the network.

Datos técnicos

  • Installation
    On the TH-35 rail
  • Power consumption [W]
    1.1
  • Width [number of modules]
    2
  • Working temperature [°C]
    from -25 to +50
  • Rated load current [A]
    16
  • Rated voltage [V]
    230
  • Level of security
    IP20
  • Width [mm]
    35
  • Rated output voltage [V]
    6

Detalles del fabricante

  • Fabricante
    F&F Filipowski S.K.
  • Dirección
    95-200 Pabianice Konstantynowska 79/81 Polska

Empaquetado a granel

una especie de paquete Sztuka
Cantidad 1 uds.
Peso (kg) 0,250
Ancho (m) 0,056
Longitud (m) 0,095
Profundidad (m) 0,070
Informar de un error