Phase failure sensor with tangent control CZF-332 CZF-332

Indice locale:
APL205FIFQ
Numero di catalogo:
CZF-332
Codice EAN:
5908312593218
Produttore: F&F
Trip voltage unbalance [V]: 40-55
Voltage hysteresis [V]: 5V~
Number of contacts: 0NO 0NC
Prezzo:
141,99 zł
gross / pezzi
(inclusa IVA 23%)
fino a 2 settimane
Su ordinazione
Quantità pezzi
(multiplo:
1
)
Aggiungi alla richiesta di preventivo
Aggiungi agli appunti
Stampa

Descrizione del prodotto

Intended use
Phase loss sensor with control of contactor contacts are designed to protect motors  supplied from a three-phase network in the event of a voltage decay in at least one phase or voltage asymmetry between the phases, and damage to the contacts of the switching contactor, which may result in the destruction of the motor. Action
Voltage failure in at least one, any phase or Trip voltage asymmetry [V] between phases above the tripping threshold will cause the motor to turn off. The switch-off will take place with a delay of 4 seconds, which prevents the motor from being disconnected in the event of a momentary voltage drop. Reactivation will occur automatically when  voltage increase by 5V above the activation voltage (i.e. by the value of the voltage hysteresis). Failure of any of the contacts of the motor-enabled contactor will permanently disable the motor. Restarting is possible only after complete disconnection of the power supply, removal of the contactor fault and reconnection. With the above anomalies, the engine cannot be started.

Dati tecnici

  • Trip voltage unbalance [V]
    40-55
  • Number of contacts
    0NO 0NC
  • Operate voltage [V]
    175-190
  • load current [A]
    10
  • Mounting method
    For screws
  • Dimensions
    3 modules (52.5mm)
  • Package height [mm]
    150
  • Package weight [kg]
    0.1
  • Voltage hysteresis [V]
    5V~
  • Power [W]
    1.6
  • Shutdown delay [s]
    4
  • connection
    2.5mm screw terminals
  • Working temperature [°C]
    -25-40
  • Power
    3×400/230V+N
  • Package width [mm]
    60
  • PKWIU
    27.12.24.0

Altri dati tecnici

  • Type of electric connection
    Screw connection
  • External power supply required
    Yes
  • Supply voltage AC 50 Hz
    150 ... 280 V
  • Phase failure detection
    Yes
  • Function over voltage detection
    No
  • Min. adjustable delay-on energization time
    4 s
  • Min. adjustable off-delay time
    4 s
  • Number of contacts as normally closed contact
    0
  • Number of contacts as change-over contact
    1
  • Operating voltage AC 50 Hz
    150 ... 280 V
  • Width
    0 mm
  • Depth
    0 mm
  • With detachable clamps
    No
  • Voltage type (supply voltage)
    AC
  • Phase sequence monitoring
    No
  • Function under voltage detection
    Yes
  • Phase imbalance monitoring
    Yes
  • Max. permitted delay-on energization time
    4 s
  • Max. permitted off-delay time
    4 s
  • Number of contacts as normally open contact
    0
  • Voltage type (operating voltage)
    AC
  • Rated switch current
    10 A
  • Height
    0 mm

Dettagli del produttore

  • Produttore
    F&F Filipowski S.K.
  • Indirizzo
    95-200 Pabianice Konstantynowska 79/81 Polska

Imballaggio sfuso

Una specie di pacchetto Sztuka
Quantità 1 pezzi
Peso (kg) 0,121
Larghezza (m) 0,056
Lunghezza (m) 0,095
Profondità (m) 0,070
Segnala un errore