Residual current circuit breaker with overcurrent. C/6KA 16A 30mA 2pole AC type ADC966D

local index:
ARB049HAGE
Catalog number:
ADC966D
EAN code:
3250611010890
Manufacturer: HAGER
Depth [mm]: 68
Number of modules: 2
Number of poles: 2
Price:
334,89 zł
gross / pcs.
(including VAT 23%)
Accessible 30 pcs.
Pickup in 1h
Quantity pcs.
(multiplicity:
1
)
Add to inquiry
Add to clipboard
Print

Product description

Residual current circuit breakers with overcurrent element Icn = 6000 A, type AC
• residual current circuit breakers with a highly sensitive overcurrent element, AC residual currents (sinusoidal alternating current),
• rated operational voltage 230 V AC,
• rated operating differential current: 30 mA,
• rated short-circuit breaking capacity: 6000 A,
• tripping characteristic for the overcurrent element: B or C,
• optical actuation indicator,
• description field with a safety flap,
• wide range of accessories,
• can be connected using horizontal comb busbars,
• cage terminals wire up to 25 mm2, stranded wire up to 16 mm2,
• degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.

Technical data

  • Depth [mm]
    68
  • Number of poles
    2
  • Differential current [mA]
    thirty
  • Power dissipation [W]
    6.4
  • Trigger type
    AC
  • Rated short-circuit breaking capacity [kA]
    6
  • PKWIU
    27.12.23.0
  • Number of modules
    2
  • Rated voltage [V]
    230
  • Rated current [A]
    16
  • Width [mm]
    35
  • Height [mm]
    83
  • Number of modules
    2

Other technical data

  • Number of poles (total)
    2
  • Rated voltage
    240 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated fault current
    0.03 A
  • Current limiting class
    3
  • Rated short-circuit breaking capacity according to IEC 60947-2
    6 kA
  • Disconnection characteristic
    Undelayed
  • Voltage type
    AC
  • Release characteristic
    C
  • With interlocking device
    Yes
  • Pollution degree
    2
  • Width in number of modular spacings
    2
  • Anti-nuisance tripping version
    No
  • Connectable conductor cross section solid-core
    1 ... 25 mm²
  • Number of protected poles
    1
  • Rated insulation voltage Ui
    500 V
  • Rated current
    16 A
  • Leakage current type
    AC
  • Power loss
    5.2 W
  • Rated short-circuit breaking capacity Icn according to EN 61009-1
    6 kA
  • Surge current capacity
    0.25 kA
  • Frequency
    50 Hz
  • Concurrently switching neutral conductor
    Yes
  • Over voltage category
    3
  • Ambient temperature during operating
    -25 ... 40 °C
  • Built-in depth
    68 mm
  • Degree of protection (IP)
    IP2X
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²

Manufacturer details

Bulk packaging

A kind of package Karton Pakiet Paleta Karton Pakiet Paleta
Quantity 1 pcs. 60 pcs. 1440 pcs. 1 pcs. 60 pcs. 1440 pcs.
Weight (kg) 0,221 13,800 351,893 0,221 13,800 351,893
Width (m) 0,080 0,310 0,800 0,080 0,310 0,800
Length (m) 0,040 0,210 0,990 0,040 0,210 0,990
Depth (m) 0,090 0,360 1,200 0,090 0,360 1,200
Report an error