Universal clamp meter, enabling current measurements up to 2000 A using clamps on wires with a diameter of up to 57 mm and busbars up to 70 x 18 mm.
The device has electronic overload protection for all functions and measuring ranges.
Provides:
- Measurement of alternating current (TRUE RMS) up to 1500 A and direct current up to 2000 A.
- Measurement of inrush current - INRUSH function.
- Measurement of direct voltage up to 1000 V and alternating voltage (TRUE RMS) up to 750 V.
- Resistance measurement and connection continuity test with audible signaling of circuit continuity (for a value lower than 30 Ω).
- Capacitance measurement.
- Temperature measurement (Fahrenheit and Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
Additionally:
- safe, insulated measuring jaws,
- automatic selection of measuring ranges ,
- the "HOLD" function, which allows you to save the result on the display,
- the "DC ZERO" function, relative measurement mode for direct current - the device can be zeroed at any time and return to measurement in the mode absolute value,
- remembering the minimum and maximum values,
- indication of exceeding the range,
- auto shutdown after 30 minutes.
Electrical safety:
- measurement category: CAT IV 600 V
- housing protection degree: IP20.
Other technical data: p>
- power supply of the meter: 9 V battery, type 6LR61,
- LCD display (liquid crystal), backlit, 4 digits (max. indication 6600), 66-segment ruler,
- continuity test: 30 Ω threshold,
- diode test: typical test current 0.8 mA, typical open circuit voltage 3.2 V DC,
- low battery indication: battery symbol is displayed,
- over range indication: 'OL,' symbol is displayed
- temperature sensor: type K thermocouple probe,
- input impedance: approx. 10 MΩ (V DC and V AC),
- AC bandwidth: 50...500 Hz,
- timed auto-off : 30 minutes.
Nominal conditions of use:
- working temperature: 0...+50°C,
- storage temperature : -20...+60°C,
- working altitude: max. 2000 m.