Residual current device with overcurrent element 1P+N 10kA B 16A/30mA Type A RCBO ADA516D

Indeks lokalny:
ARB013HAGE
Numer katalogowy:
ADA516D
Kod EAN:
3250611067764
Producent: HAGER
Rated frequency [Hz]: 50
Depth [mm]: 68
Number of poles: 2
Cena:
567,02 zł
gross / szt.
(w tym VAT 23%)
do 4 tygodni
Na zamówienie
Ilość szt.
(wielokrotność:
1
)
Dodaj do zapytania ofertowego
Dodaj do schowka
Drukuj

Opis produktu

Residual current circuit breakers with overcurrent element

Residual current circuit breakers with overcurrent element (RCBO) of high and medium sensitivity, 2-pole (1P+N),
sensitive to sinusoidal alternating (AC) or sinusoidal alternating and pulsating currents with a DC component (A),
rated operational voltage: 230 V AC,
rated operating differential current: 10, 30 or 300 mA,
short-circuit capacity Icn = 6000 A, in accordance with PN-EN61009-1,
tripping characteristic for the overcurrent element: B or C,
optical residual current trip indicator,
optical indicator of the position of the main contacts,
descriptive field with a safety flap,
wide range of accessories
possibility of connection using horizontal comb busbars,
cage terminals: (wire up to 25 mm2, strand up to 16 mm2),
degree of protection: IP2X for terminals, IP40 for the device built into the switchgear.

Dane techniczne

  • Rated frequency [Hz]
    50
  • Number of poles
    2
  • Rated insulation voltage [V]
    500
  • Rated current [A]
    16
  • Width [mm]
    35
  • Trigger type
    AND
  • Height [mm]
    83
  • Mechanical durability (number of cycles)
    2000
  • Rated impulse voltage [kV]
    4
  • Number of modules
    2
  • PKWIU
    27.12.23.0
  • Depth [mm]
    68
  • Tightening torque [Nm]
    2.1
  • Differential current [mA]
    thirty
  • Power dissipation [W]
    5.2
  • Working temperature [°C]
    -25 to 40
  • Height
    83
  • Electrical endurance (number of cycles)
    2000
  • Rated short-circuit breaking capacity [kA]
    10
  • Connection type
    With a screw
  • AC rated voltage [V]
    240

Pozostałe dane techniczne

  • Number of poles (total)
    2
  • Rated voltage
    240 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated fault current
    0.03 A
  • Current limiting class
    3
  • Rated short-circuit breaking capacity according to IEC 60947-2
    10 kA
  • Disconnection characteristic
    Undelayed
  • Voltage type
    AC
  • Release characteristic
    B
  • With interlocking device
    Yes
  • Pollution degree
    2
  • Width in number of modular spacings
    2
  • Anti-nuisance tripping version
    No
  • Connectable conductor cross section solid-core
    1 ... 25 mm²
  • Number of protected poles
    1
  • Rated insulation voltage Ui
    500 V
  • Rated current
    16 A
  • Leakage current type
    A
  • Power loss
    5.2 W
  • Rated short-circuit breaking capacity Icn according to EN 61009-1
    10 kA
  • Surge current capacity
    0.25 kA
  • Frequency
    50 Hz
  • Concurrently switching neutral conductor
    Yes
  • Over voltage category
    3
  • Ambient temperature during operating
    -25 ... 40 °C
  • Built-in depth
    68 mm
  • Degree of protection (IP)
    IP2X
  • Connectable conductor cross section multi-wired
    1 ... 16 mm²

Dane producenta

Opakowania zbiorcze

Rodzaj opakowania Karton Pakiet Paleta Karton Pakiet Paleta
Ilość 1 szt. 60 szt. 1440 szt. 1 szt. 60 szt. 1440 szt.
Waga (kg) 0,225 13,880 356,120 0,225 13,880 356,120
Szerokość (m) 0,080 0,310 0,800 0,080 0,310 0,800
Długość (m) 0,040 0,210 1,000 0,040 0,210 1,000
Głębokość (m) 0,090 0,360 1,200 0,090 0,360 1,200
Zgłoś błąd